www.california-instruments.com
9689 Towne Centre Drive, San Diego, CA 92121-1964 l (858) 677-9040 l FAX: (858) 677-0940 l [email protected]
© Copyright 2008, California Instruments Corp. Specications subject to change without notice Printed in the USA CTS 01/08
An Company
Standard controller versions with single voltage range:
Ordering Information
Dimension drawing PACS-1 / PACS-3 / PACS-3-75 unit
Note: Specications are subject to change without notice. Specications are warranted over an ambient temperature range of 25°± C. Unless otherwise noted, specications are per phase for a sinewave with a resistive
load and apply after a 30 minute warm-up period. For three phase congurations, all specications are for L-N. Phase angle specications are valid under balanced load conditions only.
Ordering Information
PC Requirements
The CTS requires the use of a PC capable of
running Win XP/2000 or Vista. Recommended
PC hardware specications are as follows:
CPU Pentium / Athlon 2.0 GHz or
faster.
RAM 1 GBytes or more.
Hard Disk 10 Gbytes or more.
30 Mbytes required for pro-
gram storage.
Display Color SVGA/XGA Monitor
Slots Available PCI slot for A/D
card.
Software MS Word, Windows
IEEE-488 For control of the power
source, a NI IEEE-488 bus
controller and available PC
slot, RS232 or USB port are
required.
California Instruments will quote a PC as part
of the system on request. Contact factory for
details.
Included with each CTS system:
-PCI CI400PCI PCI Bus, 16 bit A/D
Card.
iX Series based CTS Options:
-LR1 Lumped Reference Imped-
ance for 3/5001iX-CTS
congurations. Installed in
PACS-1.
-LR2
1
Lumped Reference Imped-
ance for 10001iX-CTS congu-
ration.
-LR3
2
Lumped Reference Imped-
ance for 15003iX-CTS. (OMNI-
3-18i)
-OMNI-3-75 Lumped Reference Imped-
ance for MX45-CTS. (OMNI-3-
75i - 3 phase)
-LR5 Japanese Lumped Reference
Impedance (100 V) for single
phase systems. (OMNI-1-37iJ)
-EOS1 EN/IEC 61000-4-11 AC source
compliance Electronic Out-
put Switch for single phase
CTS Systems.
-EOS3 EN/IEC 61000-4-11 AC source
compliance Electronic
Output Switch for 15003iX
System.
-411 EN/IEC 61000-4-11 Voltage
Dips and Interruptions test
option. (included with -EOS
options)
-413 EN/IEC 61000-4-13 Harmon-
ics and Inter-Harmonics test
option.
-LNS Internal AC Line Sync. (iX
Series only)
-XLS External AC Line Sync. (iX
Series only)
General Options:
C Cabinet. System installed in
19” instrument rack. Highly
recommended for all three
phase systems. Prex C’ to
standard model number to
order.
CIC-PC Suitable PC with preinstalled
CTS and CIGUI software.
Includes Case, keyboard,
mouse, Windows and MS
Word.
CIC-PCX Adds 17 inch monitor and
printer to CIC-PC.
-RMS Rack mount slides.
Accessories:
CI400PCI Spare PCI A/D Card
CI68C Spare 37 pin signal interface
cable for PCI.
Higher Power Systems
For higher power three phase systems, con-
tact factory.
Note 1: Required item for Flicker test.
Note 2: Option -LR3 is recommended for
15003iX-CTS systems. See App note 119 for
details.
Model VA Power AC Source EN61000-4 PACS model
Single Phase Systems
100-CTS AC Line none - PACS-1
1251RP-CTS 1250 VA 1251RP - PACS-1RP
3001iX-CTS 3000 VA 3001
iX PACS-1
5001iX-CTS (-400) 5000 VA 5001
iX (-400) PACS-1
10001iX-CTS (-400) 10000 VA 10001
iX (-400) PACS-1
Three Phase Systems
300-CTS-75 AC Line none - PACS-3-75
15003iX-CTS (-400) 15000 VA 15003
iX (-400) PACS-3
MX45-3Pi-CTS 45000 VA MX45-3Pi
PACS-3-75
For specications on the AC power source included with each CTS system, refer to
the relevant AC Source data sheet.