California Instruments 801RP Series Especificações Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 126
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 18
2.7 Environmental
Parameter
Specification
Operating Temp:
0 to +40 C
Storage Temp:
-40 to +85 C
Humidity:
Maximum relative humidity 80% for temperatures up to 31 C
decreasing linearly to 50% relative humidity at 40 C
Altitude:
2000 m maximum
Pollution Degree:
2
Installation Category
(Overvoltage Category) :
II
indoor use only
Vibration:
Designed to meet NSTA 1A transportation levels
Shock:
Designed to meet NSTA 1A transportation levels
2.8 Regulatory
Parameter
Specification
Electromagnetic
Emissions and
Immunity:
Designed to meet EN50081-1 and EN50082-1 Emissions and
Immunity standards as required for CE marking
Acoustic Noise:
65 dBA maximum at 0% to 50% load
75 dBA maximum greater than 50% load to 100% load
(measured at one meter)
Safety:
Designed to meet EN61010-1 safety standard as required for CE
marking
Remote Control
Vista de página 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 125 126

Comentários a estes Manuais

Sem comentários