California Instruments 801RP Series Especificações Página 25

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 126
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 24
3.3.1 Low Input Voltage Range Configuration (107/115 V)
In order to change the voltage range configuration:
1. Turn off the input circuit breaker.
2. Disconnect AC input power by unplugging the power cord.
3. Remove the AC Power Source top cover by removing (17) #6-32 x 5/16” FLH screws.
There are a total of 7 screws on the sides and 10 screws on the top that hold the cover.
4. The low input voltage range is set by removing the wire from CR1-AC2 and connecting it
to A4-E2.
Figure 3-3: Internal Jumper Location, Input Line Voltage 107/115
Vista de página 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 125 126

Comentários a estes Manuais

Sem comentários