California Instruments 801RP Series Manual do Utilizador Página 127

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 223
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 126
MX / RS Series SCPI Programming Manual AMETEK Programmable Power
MX / RS Series 127
TRIG:STATe?
This is a query only command. The response will define the state of the transient trigger
system as follows:
IDLE The trigger is in the idle state.
ARM The trigger is waiting for internal syncronization or external trigger
BUSY The triggered transient is in progress.
WTRIG The unit is waiting for a trigger event.
On Series II controllers, the trigger state will be updated when the last list point has been
executed. For final voltage or frequency steps with a longer dwell time than needed to reach
the end value, this means the response may change from BUSY to IDLE before the dwell
time has expired. If this affects the application program, it will be necessary to add a final list
point with a short durating (e.g. 0.001 second) to hold the BUSY state till the end of the list.
Note: Firmware revision 0.31 or lower will respond with “ARM” instead of “IDLE” at the end
of transient execution even if the trigger mode is immediate.
Query Syntax TRIGger:STATe?
Returned Parameters <CRD>
Related Commands ABOR TRIG:SOUR
TRIG:PHAS INIT INIT:CONT *TRG