8.5 MIL-STD 704E (-704)
MIL-STD 704 tests for revisions D and E only can be executed remotely from the GPIB or
RS232 using the following command tree. See the MX Series User Manual (P/N 7003-960)
or RS Series User Manual (P/N M440036) for more details about each 704 test step.
MIL-STD 704 tests for revisions A, B, C and F are implemented only through the MXGui
Windows software provided with each AC power source. As such, there are no SCPI
commands that apply to these revisions of MIL-STD 704 and they cannot be executed from
the front panel. See the MX Series User Manual (P/N 7003-960) or RS Series User Manual
(P/N M440036) and Avionics Software Manual (P/N 4994-971) for more details on
performing tests to these revisions of the standard.
This capability requires the presence of the –704 option.
8.5.1
AC System
:MIL704
:VERSion D|E
:SSTate
:VOLT
[:LEVel]
:MODulation
:UNBalance
:PHASe
[:DIFFerence]
:WAVeform
[:DISTortion]
:FREQuency
[:LEVel]
:MODulation
:TRANsient
:VOLTage
[:LOW]
:HIGH
:FREQuency
[:LOW]
:HIGH
:ABNormal
:VOLTage
[:UNDer]
:OVER
:FREQuency
[:UNDer]
:OVER
:EMERgency
:VOLTage
:FREQuency