AMETEK Programmable Power MX / RS Series SCPI Programming Manual
72 MX / RS Series
4.11 Output Subsystem
This subsystem controls the main outputs, the signal outputs and the output impedance [-3Pi
models only] of the AC/DC source.
Subsystem Syntax
OUTPut
[:STATe] <bool> Enable/disable output voltage, current, power, etc.
:IMMediate <bool> Open relay without programming down first
:PROTection
:CLEar Reset latched protection
:RI
[:LEVel] LOW | HIGH Sets Remote Inhibit input level mode.
:MODE <mode> set remote inhibit input (LATC|LIVE|OFF)
:TTLTrg
:MODE TRIG | FSTR Sets or disabled Function strobe mode.
[:STATe] <bool> Enable/disable trigger out drive
:SOURce <source> Selects a TTLTrg source (BOT|EOT|LIST)
:IMPedance
[:STATe] <bool> Enable/disable output impedance program
:REAL Sets resistive part of output impedance
:REACtive Sets inductive part of output impedance
4.11.1
Output Relay
OUTPut[:STATe]
This command enables or disables the source output. The state of a disabled output is an
output voltage amplitude set to 0 volts, with output relays opened. The query form returns
the output state.
Note: On three phase MX/RS systems with firmware revision below 0.31, it is recommended
to set the phase coupling to ALL before closing the output relay to ensure all phases are
correctly programmed. E.g. “inst:coup all:;outp 1”.
Command Syntax OUTPut[:STATe]<bool>
Parameters 0 | OFF | 1 | ON
*RST Value OFF
Examples OUTP 1 OUTP:STAT ON
Query Syntax OUTPut[:STATe]?
Returned Parameters 0 | 1
Related Commands VOLT:RANGE